SNOW GUARDS 07 72 53
SnoJax® Snow
Guards Specification Sheet:
SnoJax I
Part 1 General
- Ice
and snow guards
- Mechanically fastened or adhered to prefinished, painted or galvalume
metal roofs, except for lead coated & copper roofs.
- Snojax I (Face: 3.12”H x 5.22”W) (Mechanically fastened
only, not to be used for adhesive applications.)
- Projected cross-sectional area perpendicular to roof slope
with flat front facing toward the ridge.
- Mechanically
fastened or adhered to prefinished, painted or galvalume metal roofs,
except for lead coated & copper roofs.
- Snojax I (Minimum 5” snow holding area, for a total of at least
15 sq. inches) (Mechanically fastened only.)
- Clear
or Integrally colored per architect requirements.
Part 2 Product
- Acceptable Manufacturer
| |
IceBlox, Inc. d.b.a.
SnoBlox-SnoJax
1405 Brandton Road
Mechanicsburg, PA 17055
|
|
Phone:
1-SNOJAX-1
717-697-1999
|
|
Fax:
1-800-634-7906
717-697-6141
|
|
Online:
www.SNOBLOX-SNOJAX.com |
Materials
- Injection molded prime virgin grade polycarbonate polymer
material construction containing a UV stabilizer to prevent
damage from the ultraviolet rays of the sun.
- Izod impact strength (notched) 17 ft.-lb./in. for a 3.2mm
thick specimen
(ASTM TEST D 256)
- Thermal
ratings: deflection temperature 270° F. (ASTM TEST
D 648)
- Vicat softening temperature (Rate A)
315° F. (ASTM TEST D 1525)
- Brittleness
temperature – 150° F.
(ASTM TEST D 746)
- General
Electric "Lexan" Prime
- Dow "Cailbre" Prime
- Albis Prime
- Or approved equal of prime
quality (No Blends)
Liquid adhesive
- Surebond SB-190 sealant adhesive
Part 3 Execution
Typical
preparation
- Thoroughly
clean metal roof surface area with Xylol or isopropyl alcohol
where the snow guard is to be installed.
- Contact
SnoBlox for recommendations on snow guard location and spacing.
Installation
Options (choose 1 of 2 methods)
- Mechanically fastened
only, not to be used for adhesive applications.
- Mechanical
Fastening Installation
- Apply
a long life industrial or marine grade clear silicone
covering the entire waffled base.
- Place
snow guard in position and install corrosion-resistant
#14 self drilling screws with neoprene gasket washers
through pilot holes in the snow guard and metal roof
sheet into a purlin or structural support.
- Screws
to be tightened to cause approximately 50% compression
in neoprene gasket.
- Two
screws minimum to be installed per snow guard. Installer
to determine proper length of screws to engage purlin,
allowing for insulation
This specification sheet is provided for your use by IceBlox Inc., D.B.A. SnoBlox-Snojax.
For more information, samples and free, instant spacing layouts visit www.snojax.com, or call 800-766-5291.
SNOW GUARDS 07 72 53